Set the switch (5) to the required method of rewinding :
- Rewind with labels on the outer side of the silicon liner
- Rewind with labels on the inner side of the silicon liner
Selecting the Method of Rewinding
The external rewinder allows rewinding of labels in both ways, inside and outside
winding.
5
Connecting the Rewinder to the Power Supply
The rewinder operates with a supply voltage of 230V/ 50Hz or 115V/ 60Hz.
Before connecting the rewinder to the power supply, make sure that the
voltage selected on the power supply module is the same as your main power
supply !
F
1 - Power supply
connector
2 - Power switch
3 - Voltage selector cover
1 2 3
The current voltage setting of the power module is visible in the lid window (3).
If you have switched the operating voltage of your rewinder you need to
replace the fuses. For the standard setting of 230V, two fuses rated at
500mAT must be used. For operation at 115V, two fuses rated at 1AT must be
used. (Both types of fuses are shipped with the rewinder, one of which is
installed depending on the voltage setting.)
To alter the voltage, open the cover (3) and remove the voltage selector. Replace
the fuses as explained above. Slide the voltage selector back into the power
supply module so that the correct voltage is visible in the lid window.
Connect the rewinder to a grounded outlet using the power cable supplied in the
accessories package.