Control Panel
4
5
6
3
7
1
2
Fig. 5 Removing / mounting the control panel
Removing
X Remove the casing.
X Unlock the control panel (3) at the latch (7) swing it away from the printer and remove it by lifting.
X Unplug the connectors of the display cable (4), the cutter connection cable (5) and the ground connection cable
(6).
Mounting
X Re-connect the cables (4 to 6).
X Hook the slot (2) of the cover into the guide (1) and press the control panel against the printer until the latch (7)
clicks into place.
X Mount the casing.