78 cab - Produkttechnik GmbH & Co KG / Tharo Systems, Inc.
Error code
Type of error
HEX DEC
0001 1 dRAM fault
0002 2 dRAM multiplexer fault
0004 4 A/D converter fault
0008 8 Ribbon saver fault
0010 16 sRAM fault
0020 32 LCD damaged
0040 64 Cutter fault
0080 128 ROM fault
0100 256 Voltage fault (Apollo 3)
0200 512
0400 1024
0800 2048
1000 4096
2000 8192
4000 16384 Wrong board revision (Apollo 3)
8000 32768 Setup invalid
For the test result, the codes of occurred errors are added up to a four-digit
hexadecimal number to determine the final test result.
For example : Ribbon saver fault + LCD damaged : Test result = 0028
Table 10 Self test - Test result error codes
3 Bar Code with Test Information
This special bar code is designed for use by Technical Service. It contains
compressed information about the current configuration of the Apollo as well
as previously occurred faults.